Uncategorized

How Solar Export Rates and Time-of-Use Tariffs Change Your System Plan

Overhead photograph of solar panels on a residential roof beside neighboring houses, trees and a street.

Quick answer: Plan solar around the value of electricity—not just annual production. Electricity used on-site avoids purchases at the applicable import rate; exported electricity earns whatever credit your tariff allows. When export credits are lower than import prices, using solar directly or storing it for valuable hours can improve bill savings. California’s net billing rules illustrate this distinction, but your own utility’s terms control. (cpuc.ca.gov)

Scope: This guide uses residential service in San Diego Gas & Electric’s California territory as its named example. Tariff information was checked on October 6, 2026. It is not a nationwide rate guide, and the residential figures below should not be applied to farm or business accounts.

Start with two prices: what you avoid and what you earn

A solar proposal needs to distinguish electricity consumed on your property from electricity delivered to the grid. Under SDG&E’s Solar Billing Plan, imports and exports have separate, time-dependent values. Export credits reflect the hour when electricity reaches the grid—not simply how much the panels generate over a year. (sdge.com)

For planning purposes, think of solar’s energy-related value as:

Avoided import charges + eligible export credits

That is not a complete bill calculation. Fixed charges, credit restrictions and annual settlement rules must be handled separately.

Ask your installer to show these three quantities rather than one annual production total:

  • Solar electricity used directly on-site.
  • Solar electricity exported.
  • Electricity still purchased from the grid, separated by tariff period.

If storage is included, request a separate accounting for charging, energy losses and discharge. Do not count electricity once as an export and again as energy delivered from a battery.

This is the central planning question: What happens to each unit of production, and what is it worth when that happens? The distinction matters because California’s net billing export compensation is generally below retail electricity prices, although some late-summer evening export hours can be more valuable than retail imports. (cpuc.ca.gov)

Overhead photograph of solar panels on a residential roof beside neighboring houses, trees and a street.
Residential rooftop solar: evaluate how much production will be used on-site and how much will be exported. — Ellen Whisk. Own work Source CC BY-SA 4.0

Understand net metering, net billing and annual settlement

The terms sound similar, but they describe different ways of valuing exported electricity.

Arrangement How the California example works What to check
Net energy metering, or NEM Eligible exports receive credits based on applicable retail rates. Which charges can credits offset, and how does timing affect their value?
Net billing Imports are charged under the customer’s electricity rate; exports receive separately calculated credits. Which hourly export schedule applies to the account?
Annual settlement, or true-up Remaining balances or surplus energy are reconciled under program rules. Is annual excess compensated differently from ordinary export credits?

California’s standard NEM tariffs are closed to new enrollment. For the investor-owned utilities covered by the CPUC rules, new qualifying interconnection applications have generally moved to the net billing tariff since April 15, 2023. Utilities call it the Solar Billing Plan. Existing customers should establish their actual program before using a new-customer calculation. (cpuc.ca.gov)

Monthly export credits are not necessarily cash payments. The CPUC’s consumer guide explains that Solar Billing Plan credits can roll forward, while annual net surplus receives a separate adjustment and compensation calculation. Do not assume every exported unit retains its monthly credit value indefinitely. (cpuc.ca.gov)

SDG&E publishes multiple export-pricing downloads, including current and legacy schedules. Ask the utility to identify the correct file for your account rather than choosing one by its year alone. (sdge.com)

Check the actual time-of-use calendar

Time-of-use pricing means the cost of purchased electricity depends on when it is used. A label such as “off-peak” is not enough: you need the clock hours, weekday rules, holidays and seasonal prices.

SDG&E currently identifies EV-TOU-5 as the residential rate used with its Solar Billing Plan; commercial customers remain on their existing pricing plan. Its residential on-peak period is 4 p.m. to 9 p.m. (sdge.com)

The EV-TOU-5 rate table effective August 1, 2026 lists these summer energy charges for customers purchasing both delivery and generation from SDG&E:

Summer period Published energy charge
Super off-peak $0.13090/kWh
Off-peak $0.49627/kWh
On-peak $0.80205/kWh

These are import prices, not solar export credits, and they exclude the separately listed Base Services Charge. Winter prices differ. (sdge.com)

The current pricing calendar includes weekday super off-peak hours from midnight to 6 a.m. and 10 a.m. to 2 p.m.; weekends and listed holidays have super off-peak hours from midnight to 2 p.m. (sdge.com)

If a Community Choice Aggregator supplies your generation, do not use SDG&E’s bundled total as your complete rate. Obtain the applicable generation and export terms from that provider as well. (sdge.com)

For your proposal, request a full-year calculation using the applicable calendar—not “annual solar production multiplied by the peak rate.”

Worked example: identical solar, different export treatment

The following is an illustrative calculation, not an SDG&E tariff quotation, production measurement or savings forecast. Its deliberately simplified assumptions isolate the effect of export compensation.

Suppose, during one month:

  • The property uses 800 kWh.
  • Solar produces 600 kWh.
  • 250 kWh of solar is used directly.
  • 350 kWh is exported.
  • The property imports the remaining 550 kWh.
  • Every imported unit costs an assumed $0.30/kWh.
  • Both arrangements have the same assumed $25 monthly fixed charge.
  • All export credits in this example can offset energy charges.

Compare retail-rate export crediting with lower-rate net billing:

Calculation Retail-rate crediting Lower-rate net billing
Import charge: 550 × $0.30 $165.00 $165.00
Assumed export rate $0.30/kWh $0.05/kWh
Export credit: 350 × export rate $105.00 $17.50
Fixed charge $25.00 $25.00
Illustrative bill $85.00 $172.50

Without solar, the assumed bill would be:

800 × $0.30 + $25 = $265

Thus, identical production reduces the illustrative bill by $180 under retail-rate crediting but only $92.50 under lower-rate net billing.

Now suppose the household shifts an existing 100 kWh of consumption into hours with surplus solar. Production and total consumption remain unchanged, but imports and exports each fall by 100 kWh.

  • Under retail-rate crediting, the $30 avoided import charge replaces a $30 export credit: no change in this simplified example.
  • Under lower-rate net billing, the household avoids $30 of imports but gives up $5 of credits: $25 more monthly value.

Actual TOU calculations must use the price of the import being avoided and the export credit being surrendered. The example demonstrates arithmetic, not a guaranteed benefit from changing appliance schedules.

Let the tariff guide sizing and storage comparisons

Before requesting a larger array or battery, ask for three comparable proposals:

  1. A smaller solar-only system.
  2. The proposed solar-only system.
  3. Solar plus storage.

Keep the consumption assumptions consistent. Then compare installed cost, estimated imports, exports, remaining bills and any storage-related costs.

The CPUC advises consumers to examine a smaller-system bid because producing more electricity than the household uses annually may not justify the added installation cost. Treat expected future loads—such as an electric vehicle—as explicit assumptions, not as electricity you already consume. (cpuc.ca.gov)

A battery comparison needs another step. In a simplified energy-only calculation:

Value per kWh charged = delivered fraction × avoided later import price − forgone export credit

For illustration, assume one stored kWh delivers 0.90 kWh later, avoids a $0.40/kWh purchase and replaces a $0.05 export credit:

0.90 × $0.40 − $0.05 = $0.31

That is gross energy value per kWh charged—not battery profit. It excludes equipment, financing, degradation and replacement costs.

Request a storage model that also states:

  • Usable capacity and charging/discharging limits.
  • Expected energy losses.
  • Backup reserve settings.
  • Whether grid charging and battery exports are permitted.
  • The tariff schedule used by the controller.

Storage can move electricity into more valuable hours, but the appropriate operating strategy depends on import and export prices. California’s regulator specifically identifies using or exporting stored energy during valuable hours as a net billing opportunity. (cpuc.ca.gov)

Account for fixed charges and export limits

Fixed charges are not avoided energy purchases. SDG&E’s Base Services Charge applies to residential solar customers and is approximately $24 monthly for most customers, with discounted amounts for eligible income-qualified accounts. The exact charge depends on billing-cycle length. Solar Billing Plan export credits cannot offset this non-nettable charge. (sdge.com)

Ask the installer to distinguish:

  • Energy charges that solar can reduce.
  • Charges export credits can offset.
  • Charges that remain payable regardless of production.

Also separate export permission from export price. Receiving a credit does not establish that the utility will approve unrestricted exports from your proposed system.

SDG&E’s Limited Generation Profile process allows approved time-varying export limits, with certified controls keeping exports within the authorized profile. It can help avoid some distribution upgrades, but it does not eliminate every possible upgrade requirement. (sdge.com)

If your design includes an export limit, ask for the production estimate after that restriction is modeled. Request an explanation of whether surplus electricity will serve loads, charge storage or be curtailed. The interconnection agreement and local permitting requirements should be confirmed before installation; changing an app setting is not a substitute for approval.

Rows of solar panels across a commercial rooftop, surrounding rooftop ventilation equipment with city buildings beyond.
A large commercial rooftop array in Brooklyn; use the property’s applicable business tariff rather than residential rate assumptions. — EY418. Own work Source CC BY-SA 4.0

Questions to resolve before signing a solar contract

Send these questions to the utility or electricity provider, and retain the written answers:

  1. Which solar program and import-rate schedule will apply to this account?
  2. Which export-pricing file applies, and which prices or terms can change?
  3. What are the TOU hours, seasonal definitions and holiday rules?
  4. Which charges cannot be offset by export credits?
  5. How do credits roll forward, expire or settle annually?
  6. What export limit and interconnection conditions will apply?
  7. What are the rules for battery charging and exporting stored electricity?
  8. Could expanding an existing system affect its current tariff eligibility?

Then check the proposal for common mistakes:

  • Valuing every solar kWh at the highest import price.
  • Treating all production as an export—or all production as self-consumption.
  • Using an obsolete rate table.
  • Omitting the generation provider’s charges.
  • Counting stored electricity twice.
  • Leaving fixed charges or export restrictions out of the bill model.

For a practical final check, request a spreadsheet showing the bill without solar and the bill with each proposed system, using the same consumption profile. Have the installer identify every rate source and assumption.

Finally, ask for a sensitivity case with lower-than-estimated savings. Electricity prices, future usage and system performance can change; the CPUC cautions that a proposal’s savings estimate is not a guarantee. Choose a plan you can justify under clearly stated assumptions—not only its most optimistic forecast. (cpuc.ca.gov)